Danfoss FP715Si Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Danfoss FP715Si. FP715Si, CP715 Si and TS715 Si Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
Datasheet
MK18 Range - Electronic Time Control Range
with Service Interval
Features
The MK18 range has all the fl exibility and reliability
of its predecessor but with a more elegant look
and some handy new features. The addition of a
real time clock means that setting the time and
manually adjusting for summer winter time changes
is a thing of the past.
All units in the MK18 range are set to operate
straight from the box with default settings, but the
inclusion of a full range of customisable user and
installer settings provide ultimate fl exibility when
setting up the unit.
The MK18 range consists of 3 products:
TS715 Si / TS715Si-CB Electronic Timeswitch - A
single channel unit, with voltage free switching
contacts. Ideal for combi-boiler installations and
anywhere you require low voltage switching.
CP715 Si Common Timebase Programmer - A
two channel programmer providing heating and
hot water outputs. Each output can operate
independently of the other, with common timing
for both channels.
FP715 Si Full Programmer - A two channel
programmer providing heating and hot water
outputs. Each output can operate independently of
the other, with separate timing for each channel.
All three models use an industry standard 6
pin backplate making the MK18 range an ideal
replacement for many existing products.
24 hours / 5-2 day / 7 day programming
Factory Set Clock
Automatic Summer/Winter Time Change
Backlit Display
Built in programmes
Holiday function
Industry standard wallplate
Optional Service Interval Timer
Part No.732v02 05/08
The service interval timer allows the installer to
select a service due date for the boiler, this can
be set at between 28 days and 366 days from the
current date.
Service due date is within 28 days
From 28 days prior to the service due date, a visual
warning will appear in the display and a buzzer will
sound for ten seconds each hour commencing at
midday, this can be cancelled for the current day
by pressing any button.
Service Interval Timer
Service due date is reached or passed
When the service due date is reached the visual
and audible warning are repeated each hour of
the day commencing at midday, but the duration
of the alarm is increased to 60 seconds, this can
be cancelled for the current day by pressing any
button. All override and programming buttons
are disabled and depending upon service interval
timer setting, heating can be restricted to 15, 30 or
45 minutes in each programmed hour.
Option Service Interval Timer Function
Setting 0 Disabled, (factory default)
Setting 1 Active, visual and audible warning, no heat reduction
Setting 2 Active, visual and audible warning, heat reduced to 45 minutes per hour
Setting 3 Active, visual and audible warning, heat reduced to 30 minutes per hour
Setting 4 Active, visual and audible warning, heat reduced to 15 minutes per hour
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Datasheet

1DatasheetMK18 Range - Electronic Time Control Range with Service IntervalFeaturesThe MK18 range has all the fl exibility and reliability of its predec

Page 2 - L 1 2 3 4

2Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter it

Commentaires sur ces manuels

Pas de commentaire