Danfoss TripleLynx CN Manuel de service Page 43

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 106
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 42
Note:
PELV protection is effective up to 2000 m above sea level only.
Other factors like higher irradiation should also be taken into account. The heat-sink should be
cleaned regularly and checked for dust and blocking elements once a year.
Optimise reliability and lifetime by mounting the inverter in a location with low ambient temper-
ature.
Note:
For calculation of ventilation, consider a max. heat dissipation of 600 W per inverter.
5.3.5. Simulation of PV
Contact the supplier before connecting the inverter to a power supply for testing purposes, e.g.
simulation of PV. The inverter has built-in functionalities that may harm the power supply. For
more information, see section
Description of the Inverter, Start-up.
5. Requirements for Connection
42 L00410582-01_02
5
Vue de la page 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 105 106

Commentaires sur ces manuels

Pas de commentaire