FP975
4
GB
Specifi cation
Power supply 230 Vac ± 15%, 50/60 Hz
Switching action
2 x SPDT voltage free, Type 1B
S
Switch rating 10-230 Vac, 3(1)A
Battery back-up 24 hours minimum
Timing Accuracy ±1 min/month
Setting/Running Accuracy ±1 minute
Max. Ambient Temperature 45°C
Dimensions, mm (W, H, D) 148 x 96 x 42
Design standard EN 60730-2-7
Control Pollution Situation Degree 2
Rated Impulse Voltage 2.5kV
Ball Pressure Test 75°C
1.0 Installation Guide
2.0 System Overview
Please Note:
This product should only be installed by a qualifi ed electrician or
competent heating installer and should be in accordance with the
current edition of the IEEE wiring regulations.
Before mounting the unit, ensure the 4 DIL switches on the rear of
the unit have been moved to the required settings.
RIGHT
LEFT
TOP
MK.9
SET
PUMPED
GRAVITY
7 DAY/24 HR
5/2 DAY
24 HR
7 DAY
3.0 Installation
3.1 DIL Switch Settings