5
Wiring
COM
OFF
ON
Mains
fused
3A
TS715 (3066 12/01)
Wiring & DIL switch settings
Always switch off mains rst and never t
programmer to a live wallplate.
For Wiring Conversion tables see pages 6-9
NOTE:
Link terminals
L and 1 for
standard mains
voltage operated
systems
Remember to tick the
INSTALLER SETTING box on
the inside ap label to notify
user in which
mode their unit
is set (24hr, 5/2
day or 7 day).
DIL Switch Settings
2 ON/OFFs
2 ON/OFFs
7 DAY or 24 HOUR
24 HOUR
3 ON/OFFs
3 ON/OFFs
5/2 DAY
7 DAY
SW.1
SW.2
SW.3
SW.4
Before mounting the unit, ensure
the 4 DIL switches on the rear of
the unit have been moved to the
required settings
!
INSTALLER SETTING
24 Hour
5+2 Day
7 Day