7. Remote Connection
7.1. Remote Connection
For network management purposes, the following inverter ports are used for communication:
Application Protocol Default Port No.
WEB TCP/UDP 80 (fixed)
FTP TCP/UDP
21 (changeable), via [Setup Communication Data warehouse] on plant level
SMTP TCP/UDP
25 (changeable), via [Setup Communication SMTP] on plant level
EtherLynx UDP 48004 (fixed)
Consult the ISP for proper installation of the modem and router.
For support of third -party equipment refer to the network administrator.
Note:
Inverter Ethernet communication is not protected against internet hazards. Therefore imple-
mentation of IT safety precautions is required before connecting the inverter to the internet.
These precautions include firewall, VPN, etc.
7. Remote Connection
L00410583-01_02 57