Installation Guide DLX seriesL00410622-01 27
3.1.2.2. LED
There are three LEDs next to the display screen. The upper one is red, the middle is yellow
and the lower one is green.
Table 3.2: LEDs.
Symbol LED Function Action
Red
Malfunction! Inverter in shutdown
mode
Look for alarms in
Active Alarms
Green
&
Yellow
Caution! Inverter still operates, but at
a limited level
Look for warnings in
Active Alarms
Green
Operates; inverter feeds power to the
grid
No action
NONE Yellow
Inverter is OFF (Power < 7W
DC
) No action
3.1.2.3. LCD Screen
To navigate in the LCD screen the six function keys must be used. By selecting one of the
seven items in the Main Menu, a further navigation through different submenus is possible.
There are four different menu levels.
Figure 6.2.1: Main Menu
Home,
S
tatus, Event Log, Statistics:
The information and values are read-only.
Setup, Commands, Alarm Setup:
The information and values can be modified.
Padlock: Opens up when correct password is entered.