Two finger initialization:
1. Power off the frequency converter.
2. Press [OK] and [MENU].
3. Power up the frequency converter while still
pressing the keys above for 10 sec.
4. The frequency converter is now reset, except the
following parameters:
15-00 Operating Hours
15-03 Power Up's
15-04 Over Temp's
15-05 Over Volt's
15-4* Drive identification parameters
Initialisation of parameters is confirmed by AL80 in the
display after the power cycle.
How to Programme VLT HVAC Basic Drive Design Guide
MG.18.C2.02 - VLT
®
is a registered Danfoss trademark 63