E4 flashing in display:
Error code 4 – The thermostat has overheated
and has switched off
Let the thermostat cool for period. Then switch
the thermostat off and on.
E5 or E6 flashing in display:
Error code 5 - Floor sensor short circuited
Error code 6 - Floor sensor disconnected.
Check connections, if they are OK, then discon-
nect the 2 sensor wires and connect an ohm
meter to sensor wires.
Measure the ohm value and check with the val-
ues in the table in Technical Specifications below.
No light The system is turned off.
Green light System is standing by, set point
temperature reached
Green light flashing Floor sensor is defect
Red light System is heating
Switching between
red and green light
The floor temperature limit pre-
vents the set point room tempera-
ture from being reached.
Light Indications (LED)
The EFET
TM
535 has a LED above the 2 pole safety switch.
The LED has five indications:
Trouble shooting