30 User Guide DLX Series L00410623-1
The DLX series are single phase output inverters, which are designed so that they can be
connected to a three-phase system. When several inverters are connected together, they
must be distributed evenly between the grid phases.
Single Phase
Figure 4.3.27: Example inverter AC connections
Three Phase
Table 4.2: The different AC conductors
Term (Abbr.) Description
Phase conductor (L1/L2/L3)
The ungrounded live conductors, which carry current to the load.
Neutral conductor (N)
In a single phase system the neutral conductor is a circuit conductor
carrying the same amount of current as the ungrounded phase
conductors.
PE (Protective Earth
/
Ground) conductor
An electrical path to true Earth, designed to carry fault currents
caused by insulation breakdowns within the equipment.
4.3.5.1. Connection Procedures
Figure 4.3.28: Customer connection area with AC terminals