64 User Guide DLX Series L00410623-1
Procedure
Go to the inverter menu Alarm Setup>Notification Setup. Fill out the text fields (Refer to
6.2.6.1. Notification Setup).
• User Name and password: Usually provided by the Internet Service Provider.
• Sender email address: This is the e-mail address appearing in the From - field when
receiving mails from the inverter. It must be confi
gured as follows:
[email protected]. • Receiver 1 and 2: The recipients’ e-mail addresses.
• SMTP server: The SMTP’s server address.
NOTICE
• All IP addresses related to the inverter and web must be configured within the
range that is allowed by the local network
• For GUI revisions below v1.32, the server address must be configured with
numbers.
•
For GUI revisions v1.32 onwards: if using a domain name, the DNS IP address
needs to be specified under Setup > Network Setup.
•
Be aware that the ISP provider can change the SMTP IP address without any
notification. If the e-mail reports suddenly stops, do an nslookup to see if the IP
address has been changed!
6.1.6.2. Inverter Alarms
In Inverter Alarms the settings of notification types and time intervals of the inverter’s e-
mails to the receiver(s) must be typed in.
Notification time
Time interval (hours) for e-mailing information about the energy production
Notification time
Time interval (minutes) for e-mailing information about the energy
production
Interval
Interval between the notifications (minutes)
Send production on email 1
Specified time for sending information about energy production to email 1
Send mode on email 1
Immediately sends notification to e-mail 1 if operation mode changes
Send alarm on email 1
Immediately sends notification to e-mail 1 if warning or alarm
Send production on email 2
Specified time for sending information about energy production to email 2
Send mode on email 2
Immediately sends notification to e-mail 2 if operation mode changes
Send alarm on email 2
Immediately sends notification to e-mail 2 if warning or alarm
NOTICE
Plant Alarms is reserved for future firmware upgrade functions, and is not yet
accessible.
6.1.6.3. Portal Setup
Portal Setup displays settings for uploading data to a web portal. 15 minute average energy
data is uploaded every hour to the portal. Upload is disabled if the user name is blank. The
portal setup is compatible with the Danfoss CLX portal.