Connecting the inverters
Kaco Powador
Solar-Log
1000/500/200
Installation 25 of 268
4.3 Kaco Powador
Overview
Interface integrated
Where to connect: Terminal strip inside the inverter
2 pin wiring
Communication address must be allocated.
Work steps
Switch off the inverters and SolarLog™; Page 17
Connect inverters to the Solar-Log
Connect the inverters to each other
Allocate communication address

Note
Wiring instructions and diagram forInterconnection of Kaco Powador
inverters can be found in the Appendix; Page 264.
Connect inverters to the Solar-Log
The wiring is done using the
partly made data cable (optional extra; not supplied)
or
self-made, shielded 2 wire data cable and terminal block connector
( Page 15).
Procedure
1 Open the inverter as described in the inverter instructions.
2 Pull the free wires through the wire opening in the inverter.
3 If you have made the cable connection yourself connect the wires as
shown in the following diagram:
Solar-Log™ terminal block connector
Inverter terminal strip
Terminal
Terminal
1
B
4
A
4 If only one inverter is to be connected it must be terminated:
Series 2 Powador: Set the DIP switch inside the inverter to ON and all oth-
er inverters to OFF.
5 Close the inverter if no other inverters are to be connected.
6 Insert the terminal block connector into the Solar-Log™ RS485 socket.