Connecting the inverters
SolarMax S and C series
28 of 268 Solar-Log
1000/500/200
Installation
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using a 2 wire, shielded data cable.
Where to connect: Terminal strip inside the inverter
The RS485 connections on the terminal strip are each double connections
so that the wiring can be continued to the next inverter.
Procedure
1 Open the inverter as described in the inverter instructions.
2 Connect the data cable to the free terminals A and B of inverter 1.
3 Insert the other end of the cable into terminals A and B of inverter 2.
4 Connect the other inverters to each other in the same way.
5 Terminate in the last inverter:
Connect the free terminal A to terminal B using the supplied 330 Ω termi-
nating resistor.
6 Close inverters.
Allocate communication address
Recommendation: Continuous numbering starting with 1.
Setting: Using the DIP switch inside the inverter.
Procedure: As set out in the inverter's instructions
4.5 SolarMax S and C series
Overview
Interface integrated
Where to connect: RJ45 socket on the outside of the inverter
6 pin wiring
Communication address must be allocated.
Work steps
Switch off the inverters and the SolarLog™; Page 17
Connect inverters to the Solar-Log
Connect the inverters to each other
Allocate communication address