Connecting the inverters
Sungrow
96 of 268 Solar-Log
1000/500/200
Installation
Procedure
1 If you are fabricating the cable yourself, connect the wires as shown in the
following diagram:
Solar-Log™ terminal block connector
Inverter round socket
Terminal
Pin
1
1 (A)
4
2 (B)
2 Insert round plug into socket B on the inverter.
3 If only one inverter is to be connected terminate this in accordance with the
inverter instructions.
4 Insert the terminal block connector into the Solar-Log™ RS485 socket.
Connecting the inverters to each other (Solar-Log
500
, Solar-Log
1000
)
Connect using the RS485 cable (supplied with the inverter).
Where to connect: COM round sockets on the outside of the inverter.
Procedure
1 Insert the round plug into the COM A socket on inverter 1.
2 Insert the other end of the wire into the COM A socket on inverter 2.
3 Insert the round plug into the COM B socket on inverter 2.
4 Connect the other inverters to each other using COM A and B sockets.
5 Terminate in the last inverter in accordance with the inverter instructions.
Allocating communication address
Recommendation: Continuous numbering starting with 1.
Setting: Using the inverter operating display
Procedure: As set out in the inverter's instructions