Faults
Fault indications on the device LEDs
252 of 268 Solar-Log
1000/500/200
Installation
11 Faults
11.1 Fault indications on the device LEDs
System malfunctions
LED 1
LED 2
LED E
Meaning and possible remedy
quickly
quickly
off
For 5 min. during initialization: Error!
Pull out power plug and plug in again.
illuminated
slow
slow
Failed to read the time from the internet:
Set time manually
Check internet access
off
slow
slow
Configuration invalid or not readable:
Check interface
Check cable
Restore factory settings;
Page 259
illuminated
Only for Fronius inverters:
No data communication!
Wait for inverter feed-in
Check wiring
Check that power is present at the
interface converter
quickly
System has signalled a fault.
Fault message
Solar-Log
1000
Cancel on the touch
screen in the Diagnosis/messages
dialogue box.