Connecting the inverters
Conergy (only Solar-Log1000)
Solar-Log
1000/500/200
Installation 69 of 268
Connecting inverters to the Solar-Log
1000
Connection is only done using a ready-made data cable, specially for connect-
ing to the Solar-Log
1000
(optional extra; not supplied).
Procedure
1 Insert the CAN plug into the inverter CAN IN socket.
2 If only one inverter is to be connected it must be terminated:
Insert the two 5 pin 120 Ω terminal resistors from the ready-made cable set
into the CAN OUT socket.
3 Insert the terminal block connector into the Solar-Log
1000
CAN socket.
Connecting the inverters to each other (only Solar-Log
1000
)
Connection is made only with a ready-made data cable specially for
connecting the inverters to each other (optional extra: not supplied).
Where to connect: CAN socket outside the inverter
Procedure
1 Insert the CAN plug into any CAN OUT socket on inverter 1.
2 Insert the other end of the wire into any CAN IN socket on inverter 2.
3 Connect the other inverters to each other in the same way.
4 Terminate in the last inverter:
Insert the two 5 pin 120 Ω terminal resistors from the ready-made cable set
into the CAN OUT socket.